It is designed for the 3000 series pumps up to model 3301 and for the. Application note for replacement of xylemflygt 14 4071. It is designed for the 3000 for ex certified pumps only combinations involving series pumps up to model 3301 and for the mixer. The flygt minicas modules are relays especially designed. Technology has developed, and reading flygt minicas ii manual printable 2019 books could be far easier and much easier. The sensors are monitored by the itt flygt minicas ii supervision relay, which is situated in the panel. Legacy product minicas ii produced in sweden with external manual. It lowers your energy bill and reduces unplanned maintenance costs. Free download books flygt minicas ii manual printable 2019 everyone knows that reading flygt minicas ii manual printable 2019 is effective, because we can get enough detailed information online in the reading materials. The original minicas, pn 14 4071143, can be directly replaced by the pmr2. The mix flush valve shall be hydraulically operated to automatically close after a specified time that is integral to the pump volute.
Flygt submersible model 2670180 pump 3490 rpm 230460v. Both of these are listed in the barnes catalog in section b, page 27. Free download flygt 3202 manual pdf or read online and watch manual video on flygt n 3356 manual flygt, a xylem brand submersible pumps data sheets sustained high efficiency delivers maximum uptime and lowest cost flygt npumps handle. Jul 04, 2017 technical data technical data xylem flygt minicas ii is a supervision relay for temperature and leakage sensors. The old flygt minicas unit part numbered 14 4071 can be replaced by m. Switches o mechanical keyboards are defined by their mechanical switches.
Minicas ii, 24 vacdc, 120 vac and 230 vac supervision relay technical data itt flygt minicas ii is a supervision relay for tempera the sensors can be used in any desired combination. Sok ii w manual lock illustrated parts list shadepro a team associated mini mgt 3. Minicas ii is a monitoring relay used primarily with small and medium pumps and mixers. Itt flygt minicas module operating and maintenance itt flygt minicas module operating and maintenance manual book results. Minicas ii, 24 v acdc and 120 v ac supervision relay. Cpump, standard motor product description usage submersible pump for pumping clean water, surface water and waste water containing solids or longfibred material. This, coupled with the volutes design is what enables wastewater to flow freely. Minicas ii, 24 v acdc and 120 v ac supervision relay cross.
Flygt usa minicas ii flygts minicas ii is a supervision relay for temperature and leakage sensors. The sensors are monitored by the xylem flygt minicas ii supervision relay, which is situated in the panel. Thermal switches with fls10 the pilot cores in the pump can be connected to. With a comprehensive range of pumps to suit any task, the flygt 2600 series is the solution used to get the job done in mines and construction sites all over the world. Our flygt nevaclog has exellent flow passing properties, because parts that might cause clogging in the impeller channel have been eliminated. Minicas ii supervision relay, which is situated in the panel. The functionality of minicas ii is also incorporated in multismart and smartrun. Minicas ii, 24 v acdc and 120 v ac supervision technical data itt flygt minicas ii is a supervision relay for temperature and leakage sensors. Level range flygt only 14405081 boac001 battery operated charger and alarm unit 14405082 025120105 flasher 144071 pmr2 direct replacement for 24v minicas. Flygt usa minicas ii flygt s minicas ii is a supervision relay for temperature and leakage sensors. The minicas will send a leakage signal or shut down the pump, depending on the minicas external connections. The minicas is using only two wires for two or more.
The thermal contacts mounted inside the stator winding are connected to the microcas. Flygt minicas ii manual printable 2019 free reading at pedromoreno. The minicas ii supervision relay is installed in the pump panel and simply plugs into an eleven pin relay base. Info free download books flygt minicas ii manual printable 2019 everyone knows that reading flygt minicas ii manual printable 2019 is effective, because we can easily get enough. Minicas ii with external manual reset after an overtemperature tripping. A flygt retrofi t relay that allows the use of the existing flygt control panel including their minicas ii supervision relay. Fpump, standard motor product description usage submersible chopper pump designed for pumping liquid manure, fish waste or heavily contaminated sewage and sludge. Thermal switches with fls the pilot cores in the pump can be connected to the panel in either polarity. A slide rail adapter to allow use on the existing flygt slide rail system. When water is your challenge, flygt 2600 is your answer. Fpump, standard motor product description usage submersible chopper pump designed for pumping liquid manure, fish waste. The product with part number 14407129 mini control and status unit 120 is from company flygt and distributed with basic unit price 514,00 eur. Flygt offers minicas relays in two interchangeable variants.
Intended for transport of large volumes of water at low heads, in column installation, in the most cost effective way. The flygt minicas modules are relays especially designed to simultaneously supervise pump motor thermal switches and flygt pump leakage detectors fls stator housing andor cls waterinoil installed in each small to medium flygt pump models 3085 through 3300 or mixer series 4600. It provides protection for the most common threats against a submersible. Xylem flygt minicas ii is a supervision relay for temperature and leakage sensors. The original minicas, pn 14 4071143, can be directly replaced by the.
It provides protection for the most common threats against a submersible pump. Flygt minicas ii seal leak leakage detector supervisor relay 120v. The microcas is an electromechanical supervision relay intended for monitoring the stator temperature in flygt sewage pumps. Flygtsubmersible propeller pumps for clean, surface water. It is designed for the 3000 series pumps up to model 3301 and for the mixer program. Denomination type non explosion proof version explosion proof version.
Minicas ii fus with a manualauto reset selector switch, which allows the pump to restart in auto reset position after the stator cools down and the thermal switches reclose. Minimum permitted liquid level see the dimensional drawings of the product for the minimum permitted liquid level according to the approval for explosion proof products. Electronics part number cross reference sheet page 2 of 3 flygt pn mpe pn description 14403250 sc10032 sc100, 032ft. Macromatic offers moneysaving replacement for flygt minicas. Retrofi t sh pumps into existing flygt lift stations. Minicas iifus with a manualauto reset selector switch, which allows the pump to restart in auto reset position after the stator cools down and the thermal switches reclose. Itt flygt minicas ii is a supervision relay for temperature and leakage sensors. See the document mounting instructions, flygt cable. Thermal contacts or ptc thermistors for stator winding temperature monitoring 3 in series leakage sensor in the leakage chamber leakage sensor in the junction box pt100 sensor for main bearing temperature. Technical data technical data xylem flygt minicas ii is a supervision relay for temperature and leakage sensors. In case of alarm, the pump is stopped or an alert is given by means of lamps and relays. Flygt minicas ii manual printable 2019 in easy step and you can download it now. This monitoring relay is used primarily with small and medium pumps and mixers. A number of condition monitoring sensors are available for the itt flygt pump range.